Installation Instructions For Grand Packing
  1. Remove all the old Gland packing from stuffing box. Clean the shaft and stuffing box.
2. Check the clearance in Neck Bush and Gland follower.
3. Check the condition of sleeve and be assure that sleeve/ shaft is not scored.
4. Check the correct Gland packing size.
(ID of Stuffing box OD of Shaft/Sleeve = Correct Gland Packing size.)
                                           1/2
5. Cut the packing rings in 45° cut. The one cut end should be above the other cut end as show in fig 1
.
 
6. The joints of Gland packings should be as follows and repeat the same for more no. of rings.

7. Do not tighten the gland follower excessively.
8. Allow Gland packing to leak freely when starting up a newly packed pump.
9. Tighten the gland follower slowly at 10 minutes interval till leakage is reduced to a tolerable level.
10. Never try to stop leakage entirely.
11. If the Stuffing box has a lantern ring check it for clearance.
12. Replace Gland packing when leakage cannot be controlled by further tightening of the gland follower.
   
  Calculation Help
 
Formula
 

Calculate Gland Packing Ring Length

Shaft Speed Conversion: Metric-English

STUFFING BOX

Calculate the Stuffing Box Volume of CMS-2000

PUMPS

Calculate Pounds Per Square Inch

Calculate Head P.S.I.

Calculate Brake Horsepower

  Instructions You Must Follow Stricty While Using Insitu Mold
 
1. Remove all the material of the previous damaged packings so that the stuffing box
is absolutely clean.
2. Put two new rings properly cut at 45° and having overlapping joint staggered at 12 'O' Clock and 3 'O'
Clock position in case of 5 rings in pump
3. A. Make pieces of Insitu Mold, put these pieces around the shaft in stuffing box.
B. Tighten the gland follower with 'clean used rings'.
C Simultaneously rotate the shaft in order to form 'voidless ring'.
4. Now remove the 'old ring' and replace new ring/rings. Do not tighten gland follower excessively, i.e. the
gland follower should be finger tightened only. Now start the pump and allow initial leakage, tighten
gland follower very slowly i.e. 1/8th of turn every 20 mins to the required amount of leakage.
5. While forming ring/rings, see that one ring of Insitu Mold is formed near the gland follower,
sandwiched between two braided rings. When nos. of rings are more than 5, only outer ring of mold
should be properly formed as Zero leakage may burn the packing set.
6. Never form a ring of Insitu Mold having thickness more than the packing in use.
7. Never ever keep the gap between the joints of the ring as Insitu Mold will extrude through these gaps
either into the system or out of stuffing box.
8. Take care of flushing connection and lantern ring position, as Insitu Mold may extrude in it and block
the flushing connection.